Purge and Trap for Autosamplers and Gas Chromatography1348501

Материал из megapuper
Версия от 23:10, 2 апреля 2016; KeithwicwfjlwtcTimenez (обсуждение | вклад) (Новая страница: «Gas Chromatography (GC) is used to investigate compounds that may be vaporized without decomposing. To research these compounds, a gas chromatograph requires an a…»)
(разн.) ← Предыдущая | Текущая версия (разн.) | Следующая → (разн.)
Перейти к: навигация, поиск

Gas Chromatography (GC) is used to investigate compounds that may be vaporized without decomposing. To research these compounds, a gas chromatograph requires an autosampler whose injection mechanism meets the stress in the analysis. When lower levels of Volatile Organic Compounds (VOCs) or aroma compounds should be analyzed, a purge and trap autosampler will be the optimal choice.


The Purge and Trap Process Purge and trap autosamplers are designed for detecting compounds at the cheapest parts per billion (ppb) levels, hence their value for detecting dangerous compounds for example volatile organic, or aroma compounds that could alter the taste or scent of your product. To get ready a sample for chromatographic analysis, a purge and trap autosampler performs the following process: Bubbles carry gas through the sample release a the compounds Sequesters the compounds within the concentrator Vaporizes the compounds by heating the concentrator The vaporized compounds pass from your concentrator on the column-a number of cylindrical tubing housed inside the column oven from the chromatograph-then they reach the detector, where they're analyzed. If the analysis is finished, the outcome are displayed on an information interface, and can be printed utilizing a chart recorder. Selecting the best automatic liquid sampler and trap for Gas Chromatography is a component for your analysis of low-level compounds. Because of the essential nature from the application, choosing an autosampler with the right capabilities is an important concern. When looking for autosamplers which may have a purge and trap concentrator, researchers consider the following criteria before you make an order: Mechanical robustness- When laboratories process large volume samples, they need an autosampler whose technology can withstand the trials of the sample injection process. Analytical ability- When selecting an autosampler to the detection of low-level compounds, the secret is to decide on one which cuts down on probability of carryover between samples whenever you can. Productivity- In purge and trap autosamplers, high productivity is defined by a dual concentrator mode that accommodates liquid and soil samples, and positioning for the large number of liquid and soil samples. Simplicity of use- A user-friendly interface, intelligent software, and remote device typify an autosampler which is very easy to operate. Simple maintenance- On-board diagnostic checks, on-board real-time flow diagrams, with an error tracking and sample log make an autosampler easy to maintain. When an autosampler receives high marks in each of those categories, it's considered finer quality than your competitors. Conclusion Gas Chromatography is in charge of the security superiority various substances, from commercial soft drinks to natural pond water. To identify low levels of volatile organic compounds or another compounds of these substances, a gas chromatograph needs an autosampler that features a purge and trap concentrator. In many instances, researchers choose the autosampler depending on the criteria above, and often consider acquiring it used to save money.