Gas Chromatography (GC) is used to investigate compounds that could be vaporized without decomposing. To investigate these compounds, a gas chromatograph requires an autosampler whose injection mechanism meets the requirements of the analysis. When low levels of Chemical toxins (VOCs) or aroma compounds have to be analyzed, a purge and trap autosampler will be the optimal choice.


The Purge and Trap Process Purge and trap autosamplers are equipped for detecting compounds at the cheapest parts per billion (ppb) levels, hence their value for detecting dangerous compounds for example volatile organic, or aroma compounds which could modify the taste or scent of your product. To get ready a sample for chromatographic analysis, a purge and trap autosampler performs the next process: Bubbles carry gas from the sample to produce the compounds Sequesters the compounds from the concentrator Vaporizes the compounds by heating the concentrator The vaporized compounds pass through the concentrator for the column-a collection of cylindrical tubing housed in the column oven from the chromatograph-then they get through to the detector, where they are analyzed. When the analysis is completed, the outcomes are displayed on a knowledge interface, and can be printed using a chart recorder. Selecting the best automatic liquid sampler and trap for Gas Chromatography is a component for your analysis of low-level compounds. Due to essential nature from the application, choosing an autosampler with the right capabilities is an important concern. When shopping for autosamplers which have a purge and trap concentrator, researchers take into account the following criteria prior to an order: Mechanical robustness- When laboratories process large volume samples, they want an autosampler whose technology can withstand the pains with the sample injection process. Analytical ability- When choosing an autosampler to the detection of low-level compounds, the bottom line is to select one which cuts down on the possibility of carryover between samples wherever possible. Productivity- In purge and trap autosamplers, high productivity is scheduled by the dual concentrator mode that accommodates liquid and soil samples, and positioning for the great number of liquid and soil samples. Easy use- A user-friendly interface, intelligent software, and handy remote control typify an autosampler which is an easy task to operate. Easy maintenance- On-board diagnostic checks, on-board real-time flow diagrams, with an error tracking and sample log make an autosampler easy to maintain. When an autosampler receives high marks in every of the categories, it really is considered better than your competitors. Conclusion Gas Chromatography is responsible for the protection superiority various substances, from commercial sodas to natural pond water. To identify 'abnormal' amounts of chemical toxins or another compounds of these substances, a gas chromatograph needs an autosampler that features a purge and trap concentrator. In most cases, researchers pick the autosampler depending on the criteria above, and frequently consider buying it employed to lower your expenses.