Gas Chromatography (GC) is utilized to analyze compounds that can be vaporized without decomposing. To research these compounds, a gas chromatograph requires an autosampler whose injection mechanism meets the demands of the analysis. When 'abnormal' amounts of Volatile Organic Compounds (VOCs) or aroma compounds has to be analyzed, a purge and trap autosampler will be the optimal choice.


The Purge and Trap Process Purge and trap autosamplers can handle detecting compounds at the deepest parts per billion (ppb) levels, hence their value for detecting dangerous compounds including volatile organic, or aroma compounds that could customize the taste or scent of the product. To get ready a specimen for chromatographic analysis, a purge and trap autosampler performs the next process: Bubbles carry gas from the sample release a the compounds Sequesters the compounds from the concentrator Vaporizes the compounds by heating the concentrator The vaporized compounds pass from the concentrator on the column-a variety of cylindrical tubing housed inside the column oven with the chromatograph-then they arrive at the detector, where they are analyzed. In the event the analysis is done, the results are shown on an information interface, and can be printed by using a chart recorder. Deciding on the best automatic liquid sampler and trap for Gas Chromatography is a component for the analysis of low-level compounds. Due to the essential nature from the application, choosing an autosampler with the appropriate capabilities is a concern. When looking for autosamplers which have a purge and trap concentrator, researchers take into account the following criteria before you make a purchase order: Mechanical robustness- When laboratories process large volume samples, they desire an autosampler whose technology can withstand the pains in the sample injection process. Analytical ability- When selecting an autosampler for your detection of low-level compounds, the secret is to pick one that cuts down on the possibility of carryover between samples whenever you can. Productivity- In purge and trap autosamplers, high productivity is placed by the dual concentrator mode that accommodates liquid and soil samples, and positioning to get a large number of liquid and soil samples. Easy use- A user-friendly interface, intelligent software, and handy remote control typify an autosampler that is easy to operate. Simple maintenance- On-board diagnostic checks, on-board real-time flow diagrams, with an error tracking and sample log make an autosampler low maintenance. When an autosampler receives kudos in each of such categories, it really is considered better than the competition. Conclusion Gas Chromatography is responsible for the safety and quality of various substances, from commercial carbonated drinks to natural pond water. To detect lower levels of volatile organic compounds and other compounds in these substances, a gas chromatograph needs an autosampler that has a purge and trap concentrator. In most cases, researchers choose the autosampler using the criteria above, and often consider buying it utilized to cut costs.