Gas Chromatography (GC) can be used to research compounds that may be vaporized without decomposing. To analyze these compounds, a gas chromatograph requires an autosampler whose injection mechanism meets the stress with the analysis. When lower levels of Chemical toxins (VOCs) or aroma compounds should be analyzed, a purge and trap autosampler is the optimal choice.


The Purge and Trap Process Purge and trap autosamplers are capable of detecting compounds at the smallest parts per billion (ppb) levels, hence their value for detecting dangerous compounds for example volatile organic, or aroma compounds that can modify the taste or scent of a product. To organize an example for chromatographic analysis, a purge and trap autosampler performs the subsequent process: Bubbles carry gas through the sample to discharge the compounds Sequesters the compounds inside the concentrator Vaporizes the compounds by heating the concentrator The vaporized compounds pass from your concentrator to the column-a assortment of cylindrical tubing housed inside the column oven with the chromatograph-then they reach the detector, where these are analyzed. Once the analysis is finished, the results are shown on an information interface, and can be printed employing a chart recorder. Selecting the most appropriate automatic liquid sampler and trap for Gas Chromatography is a vital component for your analysis of low-level compounds. Due to essential nature of the application, choosing an autosampler with the right capabilities is a concern. When researching autosamplers which have a purge and trap concentrator, researchers think about the following criteria before making an investment: Mechanical robustness- When laboratories process large volume samples, they need an autosampler whose technology can withstand the pains of the sample injection process. Analytical ability- When selecting an autosampler to the detection of low-level compounds, the secret is to select one which decreases the chance of carryover between samples wherever possible. Productivity- In purge and trap autosamplers, high productivity is placed by a dual concentrator mode that accommodates liquid and soil samples, and positioning for a great number of liquid and soil samples. Simple use- A user-friendly interface, intelligent software, and handy remote control typify an autosampler that is certainly simple to operate. Ease of maintenance- On-board diagnostic checks, on-board real-time flow diagrams, and an error tracking and sample log make an autosampler low maintenance. When an autosampler receives kudos in every of such categories, it is considered more advanced than your competition. Conclusion Gas Chromatography accounts for the security and quality of various substances, from commercial sodas to natural pond water. To detect low levels of volatile organic compounds and other compounds in these substances, a gas chromatograph needs an autosampler that features a purge and trap concentrator. Typically, researchers choose the autosampler based on the criteria above, and quite often consider acquiring it employed to cut costs.