Gas Chromatography (GC) is employed to investigate compounds that can be vaporized without decomposing. To research these compounds, a gas chromatograph requires an autosampler whose injection mechanism meets the requirements with the analysis. When lower levels of Volatile Organic Compounds (VOCs) or aroma compounds must be analyzed, a purge and trap autosampler may be the optimal choice.


The Purge and Trap Process Purge and trap autosamplers are designed for detecting compounds at the deepest parts per billion (ppb) levels, hence their value for detecting dangerous compounds including volatile organic, or aroma compounds that can customize the taste or scent of the product. To arrange a specimen for chromatographic analysis, a purge and trap autosampler performs the subsequent process: Bubbles carry gas with the sample to release the compounds Sequesters the compounds within the concentrator Vaporizes the compounds by heating the concentrator The vaporized compounds pass in the concentrator for the column-a number of cylindrical tubing housed from the column oven in the chromatograph-then they get through to the detector, where they're analyzed. When the analysis is complete, the final results are shown on a knowledge interface, and is printed utilizing a chart recorder. Deciding on the best automatic liquid sampler and trap for Gas Chromatography is an important component for the analysis of low-level compounds. Due to essential nature in the application, choosing an autosampler with the proper capabilities is a concern. When searching for autosamplers who have a purge and trap concentrator, researchers think about the following criteria before you make an order: Mechanical robustness- When laboratories process large volume samples, they desire an autosampler whose technology can withstand the trials from the sample injection process. Analytical ability- When scouting for an autosampler for your detection of low-level compounds, the secret is to pick the one that reduces the potential for carryover between samples whenever you can. Productivity- In purge and trap autosamplers, high productivity is scheduled by a dual concentrator mode that accommodates liquid and soil samples, and positioning for the large number of liquid and soil samples. Ease of use- A user-friendly interface, intelligent software, and remote device typify an autosampler which is very easy to operate. Simplicity of maintenance- On-board diagnostic checks, on-board real-time flow diagrams, with an error tracking and sample log make an autosampler easy to maintain. When an autosampler receives high marks in every of those categories, it is considered better than the competition. Conclusion Gas Chromatography is liable for the safety and quality of various substances, from commercial carbonated drinks to natural pond water. To identify 'abnormal' amounts of volatile organic compounds or any other compounds in these substances, a gas chromatograph needs an autosampler which includes a purge and trap concentrator. Generally, researchers select the autosampler in line with the criteria above, and sometimes consider buying it employed to cut costs.