Gas Chromatography (GC) is employed to evaluate compounds which can be vaporized without decomposing. To evaluate these compounds, a gas chromatograph requires an autosampler whose injection mechanism meets the strain with the analysis. When lower levels of Chemical toxins (VOCs) or aroma compounds should be analyzed, a purge and trap autosampler is the optimal choice.


The Purge and Trap Process Purge and trap autosamplers can handle detecting compounds at the smallest parts per billion (ppb) levels, hence their value for detecting dangerous compounds including volatile organic, or aroma compounds that may alter the taste or scent of a product. To organize an example for chromatographic analysis, a purge and trap autosampler performs the next process: Bubbles carry gas with the sample to release the compounds Sequesters the compounds in the concentrator Vaporizes the compounds by heating the concentrator The vaporized compounds pass through the concentrator to the column-a number of cylindrical tubing housed inside the column oven with the chromatograph-then they arrive at the detector, where they may be analyzed. Once the analysis is completed, the final results are shown on an information interface, and can be printed using a chart recorder. Selecting the most appropriate automatic liquid sampler and trap for Gas Chromatography is a vital component to the analysis of low-level compounds. Because of the essential nature in the application, choosing an autosampler with the appropriate capabilities is a vital concern. When researching autosamplers that have a purge and trap concentrator, researchers consider the following criteria before you make an order: Mechanical robustness- When laboratories process large volume samples, they need an autosampler whose technology can withstand the pains in the sample injection process. Analytical ability- When selecting an autosampler for the detection of low-level compounds, the secret is to pick the one that decreases the possibility of carryover between samples wherever possible. Productivity- In purge and trap autosamplers, high productivity is scheduled by a dual concentrator mode that accommodates liquid and soil samples, and positioning for a large number of liquid and soil samples. Simplicity of use- A user-friendly interface, intelligent software, and remote device typify an autosampler that's very easy to operate. Ease of maintenance- On-board diagnostic checks, on-board real-time flow diagrams, as well as an error tracking and sample log make an autosampler low maintenance. When an autosampler receives high marks in each of such categories, it can be considered better than competition. Conclusion Gas Chromatography accounts for the safety and excellence of various substances, from commercial sodas to natural pond water. To detect low levels of volatile organic compounds or any other compounds over these substances, a gas chromatograph needs an autosampler that includes a purge and trap concentrator. In most cases, researchers find the autosampler in line with the criteria above, and frequently consider buying it employed to cut costs.