Gas Chromatography (GC) can be used to investigate compounds that could be vaporized without decomposing. To evaluate these compounds, a gas chromatograph requires an autosampler whose injection mechanism meets the strain of the analysis. When low levels of Volatile Organic Compounds (VOCs) or aroma compounds have to be analyzed, a purge and trap autosampler could be the optimal choice.


The Purge and Trap Process Purge and trap autosamplers are equipped for detecting compounds at the smallest parts per billion (ppb) levels, hence their value for detecting dangerous compounds such as volatile organic, or aroma compounds which could affect the taste or scent of your product. To prepare an example for chromatographic analysis, a purge and trap autosampler performs the following process: Bubbles carry gas over the sample to discharge the compounds Sequesters the compounds inside the concentrator Vaporizes the compounds by heating the concentrator The vaporized compounds pass from your concentrator towards the column-a variety of cylindrical tubing housed in the column oven of the chromatograph-then they reach the detector, where they may be analyzed. When the analysis is complete, the outcome are displayed on a knowledge interface, and can be printed employing a chart recorder. Selecting the best automatic liquid sampler and trap for Gas Chromatography is a crucial component for that analysis of low-level compounds. Due to essential nature of the application, choosing an autosampler with the proper capabilities is a crucial concern. When searching for autosamplers who have a purge and trap concentrator, researchers look at the following criteria prior to making a purchase order: Mechanical robustness- When laboratories process large volume samples, they require an autosampler whose technology can withstand the trials of the sample injection process. Analytical ability- When choosing an autosampler for your detection of low-level compounds, the hot button is to pick the one that reduces the probability of carryover between samples as much as possible. Productivity- In purge and trap autosamplers, high productivity is defined by the dual concentrator mode that accommodates liquid and soil samples, and positioning for the large numbers of liquid and soil samples. Ease of use- A user-friendly interface, intelligent software, and remote control typify an autosampler that's very easy to operate. Simplicity of maintenance- On-board diagnostic checks, on-board real-time flow diagrams, with an error tracking and sample log make an autosampler low maintenance. When an autosampler receives kudos in every of those categories, it can be considered more advanced than the competition. Conclusion Gas Chromatography accounts for the protection and quality of various substances, from commercial sodas to natural pond water. To identify lower levels of chemical toxins or other compounds over these substances, a gas chromatograph needs an autosampler that features a purge and trap concentrator. In most cases, researchers choose the autosampler using the criteria above, and often consider purchasing it employed to cut costs.