Purge and Trap for Autosamplers and Gas Chromatography6360607

Материал из megapuper
Версия от 22:48, 2 апреля 2016; CarolannxlkpyrpukqNiedens (обсуждение | вклад) (Новая страница: «Gas Chromatography (GC) can be used to evaluate compounds that can be vaporized without decomposing. To research these compounds, a gas chromatograph requires an…»)
(разн.) ← Предыдущая | Текущая версия (разн.) | Следующая → (разн.)
Перейти к: навигация, поиск

Gas Chromatography (GC) can be used to evaluate compounds that can be vaporized without decomposing. To research these compounds, a gas chromatograph requires an autosampler whose injection mechanism meets the strain with the analysis. When low levels of Volatile Organic Compounds (VOCs) or aroma compounds must be analyzed, a purge and trap autosampler may be the optimal choice.


The Purge and Trap Process Purge and trap autosamplers can handle detecting compounds at the cheapest parts per billion (ppb) levels, hence their value for detecting dangerous compounds such as volatile organic, or aroma compounds that could customize the taste or scent of your product. To get ready a specimen for chromatographic analysis, a purge and trap autosampler performs the next process: Bubbles carry gas from the sample to release the compounds Sequesters the compounds in the concentrator Vaporizes the compounds by heating the concentrator The vaporized compounds pass from the concentrator towards the column-a number of cylindrical tubing housed from the column oven with the chromatograph-then they reach the detector, where they are analyzed. In the event the analysis is done, the outcome are shown on a knowledge interface, and can be printed by using a chart recorder. Selecting the best automatic liquid sampler and trap for Gas Chromatography is a component for that analysis of low-level compounds. As a result of essential nature from the application, choosing an autosampler with the right capabilities is an important concern. When researching autosamplers which may have a purge and trap concentrator, researchers think about the following criteria before you make an order: Mechanical robustness- When laboratories process large volume samples, they want an autosampler whose technology can withstand the rigors with the sample injection process. Analytical ability- When scouting for an autosampler for that detection of low-level compounds, the bottom line is to select the one which reduces the chance of carryover between samples wherever possible. Productivity- In purge and trap autosamplers, high productivity is placed by the dual concentrator mode that accommodates liquid and soil samples, and positioning for any large numbers of liquid and soil samples. Simplicity of use- A user-friendly interface, intelligent software, and remote control typify an autosampler that's an easy task to operate. Simple maintenance- On-board diagnostic checks, on-board real-time flow diagrams, and an error tracking and sample log make an autosampler low maintenance. When an autosampler receives high marks in every of those categories, it really is considered more advanced than competition. Conclusion Gas Chromatography is liable for the safety and quality of various substances, from commercial soft drinks to natural pond water. To identify 'abnormal' amounts of volatile organic compounds or any other compounds in these substances, a gas chromatograph needs an autosampler which includes a purge and trap concentrator. Generally, researchers pick the autosampler depending on the criteria above, and sometimes consider buying it utilized to lower your expenses.