Gas Chromatography (GC) can be used to investigate compounds that may be vaporized without decomposing. To evaluate these compounds, a gas chromatograph requires an autosampler whose injection mechanism meets the demands from the analysis. When low levels of Volatile Organic Compounds (VOCs) or aroma compounds has to be analyzed, a purge and trap autosampler is the optimal choice.


The Purge and Trap Process Purge and trap autosamplers are equipped for detecting compounds at the smallest parts per billion (ppb) levels, hence their value for detecting dangerous compounds such as volatile organic, or aroma compounds which could affect the taste or scent of an product. To organize a sample for chromatographic analysis, a purge and trap autosampler performs the next process: Bubbles carry gas over the sample to release the compounds Sequesters the compounds within the concentrator Vaporizes the compounds by heating the concentrator The vaporized compounds pass from your concentrator for the column-a variety of cylindrical tubing housed in the column oven in the chromatograph-then they get through to the detector, where they're analyzed. When the analysis is completed, the outcome are shown on a data interface, and can be printed employing a chart recorder. Choosing the Right automatic liquid sampler and trap for Gas Chromatography is a vital component for that analysis of low-level compounds. As a result of essential nature from the application, choosing an autosampler with the proper capabilities is a concern. When looking for autosamplers that have a purge and trap concentrator, researchers think about the following criteria prior to an order: Mechanical robustness- When laboratories process large volume samples, they want an autosampler whose technology can withstand the rigors in the sample injection process. Analytical ability- When scouting for an autosampler for your detection of low-level compounds, the hot button is to pick the one that cuts down on probability of carryover between samples whenever you can. Productivity- In purge and trap autosamplers, high productivity is scheduled by the dual concentrator mode that accommodates liquid and soil samples, and positioning for any many liquid and soil samples. Simple use- A user-friendly interface, intelligent software, and handy remote control typify an autosampler that is certainly simple to operate. Simple maintenance- On-board diagnostic checks, on-board real-time flow diagrams, plus an error tracking and sample log make an autosampler easy to maintain. When an autosampler receives kudos in each of such categories, it really is considered superior to the competition. Conclusion Gas Chromatography is liable for the safety and quality of various substances, from commercial sodas to natural pond water. To identify low levels of volatile organic compounds and other compounds of these substances, a gas chromatograph needs an autosampler which includes a purge and trap concentrator. Typically, researchers choose the autosampler depending on the criteria above, and frequently consider purchasing it accustomed to spend less.