Gas Chromatography (GC) is used to analyze compounds that could be vaporized without decomposing. To evaluate these compounds, a gas chromatograph requires an autosampler whose injection mechanism meets the requirements with the analysis. When 'abnormal' amounts of Volatile Organic Compounds (VOCs) or aroma compounds must be analyzed, a purge and trap autosampler will be the optimal choice.


The Purge and Trap Process Purge and trap autosamplers can handle detecting compounds at the cheapest parts per billion (ppb) levels, hence their value for detecting dangerous compounds such as volatile organic, or aroma compounds that can modify the taste or scent of the product. To get ready a sample for chromatographic analysis, a purge and trap autosampler performs the subsequent process: Bubbles carry gas from the sample to discharge the compounds Sequesters the compounds from the concentrator Vaporizes the compounds by heating the concentrator The vaporized compounds pass from your concentrator for the column-a collection of cylindrical tubing housed inside the column oven from the chromatograph-then they get through the detector, where these are analyzed. Once the analysis is complete, the outcomes are displayed on an information interface, and could be printed utilizing a chart recorder. Selecting the most appropriate automatic liquid sampler and trap for Gas Chromatography is an important component for that analysis of low-level compounds. As a result of essential nature from the application, choosing an autosampler with the appropriate capabilities is a concern. When researching autosamplers which have a purge and trap concentrator, researchers look at the following criteria before making a purchase: Mechanical robustness- When laboratories process large volume samples, they desire an autosampler whose technology can withstand the pains of the sample injection process. Analytical ability- When scouting for an autosampler for that detection of low-level compounds, the bottom line is to decide on one that decreases the probability of carryover between samples whenever possible. Productivity- In purge and trap autosamplers, high productivity is placed with a dual concentrator mode that accommodates liquid and soil samples, and positioning for the many liquid and soil samples. Ease of use- A user-friendly interface, intelligent software, and remote device typify an autosampler which is easy to operate. Ease of maintenance- On-board diagnostic checks, on-board real-time flow diagrams, plus an error tracking and sample log make an autosampler low maintenance. When an autosampler receives high marks in every of these categories, it's considered more advanced than competition. Conclusion Gas Chromatography is liable for the safety and quality of various substances, from commercial carbonated drinks to natural pond water. To identify 'abnormal' amounts of volatile organic compounds or another compounds in these substances, a gas chromatograph needs an autosampler that includes a purge and trap concentrator. In most cases, researchers select the autosampler using the criteria above, and quite often consider buying it employed to lower your expenses.