Gas Chromatography (GC) can be used to analyze compounds that can be vaporized without decomposing. To analyze these compounds, a gas chromatograph requires an autosampler whose injection mechanism meets the stress of the analysis. When low levels of Volatile Organic Compounds (VOCs) or aroma compounds should be analyzed, a purge and trap autosampler will be the optimal choice.


The Purge and Trap Process Purge and trap autosamplers are designed for detecting compounds at the cheapest parts per billion (ppb) levels, hence their value for detecting dangerous compounds such as volatile organic, or aroma compounds which could alter the taste or scent of an product. To arrange a specimen for chromatographic analysis, a purge and trap autosampler performs the next process: Bubbles carry gas with the sample release a the compounds Sequesters the compounds in the concentrator Vaporizes the compounds by heating the concentrator The vaporized compounds pass from your concentrator towards the column-a collection of cylindrical tubing housed inside the column oven from the chromatograph-then they reach the detector, where these are analyzed. In the event the analysis is complete, the results are shown on a data interface, and is printed using a chart recorder. Choosing the Right automatic liquid sampler and trap for Gas Chromatography is an important component for your analysis of low-level compounds. Due to the essential nature with the application, choosing an autosampler with the appropriate capabilities is a concern. When searching for autosamplers that have a purge and trap concentrator, researchers think about the following criteria before making a purchase order: Mechanical robustness- When laboratories process large volume samples, they desire an autosampler whose technology can withstand the pains with the sample injection process. Analytical ability- In choosing an autosampler to the detection of low-level compounds, the bottom line is to select the one that cuts down on chance of carryover between samples wherever possible. Productivity- In purge and trap autosamplers, high productivity is placed with a dual concentrator mode that accommodates liquid and soil samples, and positioning for any great number of liquid and soil samples. Simplicity of use- A user-friendly interface, intelligent software, and handheld remote control typify an autosampler that is certainly easy to operate. Simple maintenance- On-board diagnostic checks, on-board real-time flow diagrams, with an error tracking and sample log make an autosampler low maintenance. When an autosampler receives high marks in each of the categories, it really is considered more advanced than your competitors. Conclusion Gas Chromatography is in charge of the security and excellence of various substances, from commercial soft drinks to natural pond water. To detect low levels of volatile organic compounds or another compounds during these substances, a gas chromatograph needs an autosampler which includes a purge and trap concentrator. Generally, researchers find the autosampler depending on the criteria above, and frequently consider buying it accustomed to cut costs.