Gas Chromatography (GC) is employed to evaluate compounds that could be vaporized without decomposing. To analyze these compounds, a gas chromatograph requires an autosampler whose injection mechanism meets the strain with the analysis. When lower levels of Volatile Organic Compounds (VOCs) or aroma compounds should be analyzed, a purge and trap autosampler will be the optimal choice.


The Purge and Trap Process Purge and trap autosamplers are equipped for detecting compounds at the deepest parts per billion (ppb) levels, hence their value for detecting dangerous compounds for example volatile organic, or aroma compounds that may customize the taste or scent of an product. To get ready a sample for chromatographic analysis, a purge and trap autosampler performs these process: Bubbles carry gas over the sample to release the compounds Sequesters the compounds within the concentrator Vaporizes the compounds by heating the concentrator The vaporized compounds pass in the concentrator for the column-a number of cylindrical tubing housed within the column oven of the chromatograph-then they reach the detector, where they may be analyzed. In the event the analysis is finished, the final results are shown on a data interface, and can be printed using a chart recorder. Choosing the Right automatic liquid sampler and trap for Gas Chromatography is a vital component for the analysis of low-level compounds. Because of the essential nature in the application, choosing an autosampler with the proper capabilities is a vital concern. When shopping for autosamplers which have a purge and trap concentrator, researchers look at the following criteria prior to an order: Mechanical robustness- When laboratories process large volume samples, they need an autosampler whose technology can withstand the pains of the sample injection process. Analytical ability- When selecting an autosampler for your detection of low-level compounds, the secret is to select one which reduces the potential for carryover between samples whenever you can. Productivity- In purge and trap autosamplers, high productivity is defined by way of a dual concentrator mode that accommodates liquid and soil samples, and positioning for any large number of liquid and soil samples. Easy use- A user-friendly interface, intelligent software, and remote control typify an autosampler that is easy to operate. Simple maintenance- On-board diagnostic checks, on-board real-time flow diagrams, plus an error tracking and sample log make an autosampler low maintenance. When an autosampler receives high marks in each of the categories, it really is considered more advanced than your competitors. Conclusion Gas Chromatography is liable for the protection superiority various substances, from commercial sodas to natural pond water. To detect low levels of chemical toxins and other compounds during these substances, a gas chromatograph needs an autosampler that features a purge and trap concentrator. Typically, researchers pick the autosampler depending on the criteria above, and sometimes consider acquiring it used to lower your expenses.