Purge and Trap for Autosamplers and Gas Chromatography8647316

Материал из megapuper
Версия от 23:16, 2 апреля 2016; ZachariahojobuwkwgfLickey (обсуждение | вклад) (Новая страница: «Gas Chromatography (GC) is employed to investigate compounds that may be vaporized without decomposing. To evaluate these compounds, a gas chromatograph requires…»)
(разн.) ← Предыдущая | Текущая версия (разн.) | Следующая → (разн.)
Перейти к: навигация, поиск

Gas Chromatography (GC) is employed to investigate compounds that may be vaporized without decomposing. To evaluate these compounds, a gas chromatograph requires an autosampler whose injection mechanism meets the strain of the analysis. When 'abnormal' amounts of Chemical toxins (VOCs) or aroma compounds should be analyzed, a purge and trap autosampler is the optimal choice.


The Purge and Trap Process Purge and trap autosamplers are capable of detecting compounds at the smallest parts per billion (ppb) levels, hence their value for detecting dangerous compounds including volatile organic, or aroma compounds that could affect the taste or scent of the product. To get ready a specimen for chromatographic analysis, a purge and trap autosampler performs the following process: Bubbles carry gas from the sample release a the compounds Sequesters the compounds from the concentrator Vaporizes the compounds by heating the concentrator The vaporized compounds pass through the concentrator to the column-a assortment of cylindrical tubing housed in the column oven from the chromatograph-then they arrive at the detector, where they may be analyzed. Once the analysis is finished, the final results are shown on an information interface, and can be printed by using a chart recorder. Deciding on the best automatic liquid sampler and trap for Gas Chromatography is a vital component to the analysis of low-level compounds. Due to the essential nature with the application, choosing an autosampler with the proper capabilities is an important concern. When looking for autosamplers which may have a purge and trap concentrator, researchers consider the following criteria prior to making a purchase: Mechanical robustness- When laboratories process large volume samples, they need an autosampler whose technology can withstand the pains of the sample injection process. Analytical ability- When selecting an autosampler to the detection of low-level compounds, the key is to select one that reduces the potential for carryover between samples whenever you can. Productivity- In purge and trap autosamplers, high productivity is placed by the dual concentrator mode that accommodates liquid and soil samples, and positioning for the great number of liquid and soil samples. Easy use- A user-friendly interface, intelligent software, and remote device typify an autosampler that is easy to operate. Simplicity of maintenance- On-board diagnostic checks, on-board real-time flow diagrams, and an error tracking and sample log make an autosampler low maintenance. When an autosampler receives high marks in every of the categories, it's considered superior to your competition. Conclusion Gas Chromatography is liable for the safety and quality of various substances, from commercial sodas to natural pond water. To identify lower levels of volatile organic compounds or other compounds over these substances, a gas chromatograph needs an autosampler that has a purge and trap concentrator. Typically, researchers pick the autosampler in line with the criteria above, and often consider acquiring it employed to spend less.