Purge and Trap for Autosamplers and Gas Chromatography3187648

Материал из megapuper
Перейти к: навигация, поиск

Gas Chromatography (GC) is employed to investigate compounds that could be vaporized without decomposing. To research these compounds, a gas chromatograph requires an autosampler whose injection mechanism meets the stress of the analysis. When low levels of Volatile Organic Compounds (VOCs) or aroma compounds has to be analyzed, a purge and trap autosampler may be the optimal choice.


The Purge and Trap Process Purge and trap autosamplers are designed for detecting compounds at the lowest parts per billion (ppb) levels, hence their value for detecting dangerous compounds such as volatile organic, or aroma compounds which could modify the taste or scent of the product. To organize a sample for chromatographic analysis, a purge and trap autosampler performs the subsequent process: Bubbles carry gas over the sample to discharge the compounds Sequesters the compounds from the concentrator Vaporizes the compounds by heating the concentrator The vaporized compounds pass from your concentrator on the column-a assortment of cylindrical tubing housed from the column oven from the chromatograph-then they arrive at the detector, where they are analyzed. When the analysis is finished, the outcomes are shown on a knowledge interface, and could be printed using a chart recorder. Deciding on the best automatic liquid sampler and trap for Gas Chromatography is a component to the analysis of low-level compounds. Due to the essential nature of the application, choosing an autosampler with the right capabilities is a vital concern. When looking for autosamplers which have a purge and trap concentrator, researchers take into account the following criteria before you make a purchase: Mechanical robustness- When laboratories process large volume samples, they desire an autosampler whose technology can withstand the pains from the sample injection process. Analytical ability- When scouting for an autosampler to the detection of low-level compounds, the key is to pick one that cuts down on the probability of carryover between samples whenever you can. Productivity- In purge and trap autosamplers, high productivity is defined by a dual concentrator mode that accommodates liquid and soil samples, and positioning for any large numbers of liquid and soil samples. Ease of use- A user-friendly interface, intelligent software, and remote device typify an autosampler that's simple to operate. Simplicity of maintenance- On-board diagnostic checks, on-board real-time flow diagrams, with an error tracking and sample log make an autosampler low maintenance. When an autosampler receives kudos in every of these categories, it really is considered more advanced than your competition. Conclusion Gas Chromatography is responsible for the protection and quality of various substances, from commercial carbonated drinks to natural pond water. To detect low levels of volatile organic compounds or other compounds in these substances, a gas chromatograph needs an autosampler that has a purge and trap concentrator. In most cases, researchers choose the autosampler based on the criteria above, and frequently consider purchasing it used to cut costs.