Gas Chromatography (GC) is employed to investigate compounds that may be vaporized without decomposing. To evaluate these compounds, a gas chromatograph requires an autosampler whose injection mechanism meets the strain with the analysis. When 'abnormal' amounts of Volatile Organic Compounds (VOCs) or aroma compounds have to be analyzed, a purge and trap autosampler may be the optimal choice.


The Purge and Trap Process Purge and trap autosamplers are equipped for detecting compounds at the cheapest parts per billion (ppb) levels, hence their value for detecting dangerous compounds such as volatile organic, or aroma compounds which could alter the taste or scent of the product. To prepare a sample for chromatographic analysis, a purge and trap autosampler performs the following process: Bubbles carry gas with the sample to release the compounds Sequesters the compounds in the concentrator Vaporizes the compounds by heating the concentrator The vaporized compounds pass in the concentrator for the column-a collection of cylindrical tubing housed within the column oven of the chromatograph-then they reach the detector, where they are analyzed. Once the analysis is completed, the final results are displayed on a data interface, and is printed by using a chart recorder. Selecting the best automatic liquid sampler and trap for Gas Chromatography is an important component for that analysis of low-level compounds. As a result of essential nature with the application, choosing an autosampler with the appropriate capabilities is an important concern. When researching autosamplers which have a purge and trap concentrator, researchers look at the following criteria prior to making an order: Mechanical robustness- When laboratories process large volume samples, they need an autosampler whose technology can withstand the pains in the sample injection process. Analytical ability- When scouting for an autosampler for the detection of low-level compounds, the hot button is to choose the one that decreases the potential for carryover between samples whenever possible. Productivity- In purge and trap autosamplers, high productivity is determined by a dual concentrator mode that accommodates liquid and soil samples, and positioning for any many liquid and soil samples. Easy use- A user-friendly interface, intelligent software, and remote device typify an autosampler that is certainly very easy to operate. Ease of maintenance- On-board diagnostic checks, on-board real-time flow diagrams, with an error tracking and sample log make an autosampler low maintenance. When an autosampler receives high marks in each of these categories, it really is considered better than your competitors. Conclusion Gas Chromatography accounts for the safety superiority various substances, from commercial carbonated drinks to natural pond water. To identify 'abnormal' amounts of volatile organic compounds or any other compounds of these substances, a gas chromatograph needs an autosampler that includes a purge and trap concentrator. In most cases, researchers select the autosampler using the criteria above, and sometimes consider purchasing it used to spend less.