Purge and Trap for Autosamplers and Gas Chromatography8931546

Материал из megapuper
Перейти к: навигация, поиск

Gas Chromatography (GC) is employed to evaluate compounds that could be vaporized without decomposing. To research these compounds, a gas chromatograph requires an autosampler whose injection mechanism meets the demands from the analysis. When low levels of Chemical toxins (VOCs) or aroma compounds have to be analyzed, a purge and trap autosampler is the optimal choice.


The Purge and Trap Process Purge and trap autosamplers are designed for detecting compounds at the deepest parts per billion (ppb) levels, hence their value for detecting dangerous compounds including volatile organic, or aroma compounds that may alter the taste or scent of the product. To organize a sample for chromatographic analysis, a purge and trap autosampler performs the following process: Bubbles carry gas over the sample to release the compounds Sequesters the compounds inside the concentrator Vaporizes the compounds by heating the concentrator The vaporized compounds pass in the concentrator on the column-a number of cylindrical tubing housed within the column oven of the chromatograph-then they arrive at the detector, where they may be analyzed. In the event the analysis is complete, the final results are displayed on an information interface, and can be printed by using a chart recorder. Deciding on the best automatic liquid sampler and trap for Gas Chromatography is a crucial component for the analysis of low-level compounds. Because of the essential nature from the application, choosing an autosampler with the appropriate capabilities is a vital concern. When researching autosamplers that have a purge and trap concentrator, researchers look at the following criteria prior to making an order: Mechanical robustness- When laboratories process large volume samples, they want an autosampler whose technology can withstand the trials of the sample injection process. Analytical ability- When choosing an autosampler for your detection of low-level compounds, the key is to select one that reduces the potential for carryover between samples as much as possible. Productivity- In purge and trap autosamplers, high productivity is placed by a dual concentrator mode that accommodates liquid and soil samples, and positioning for the large numbers of liquid and soil samples. Ease of use- A user-friendly interface, intelligent software, and remote device typify an autosampler that's simple to operate. Ease of maintenance- On-board diagnostic checks, on-board real-time flow diagrams, with an error tracking and sample log make an autosampler low maintenance. When an autosampler receives high marks in each of the categories, it can be considered better than your competitors. Conclusion Gas Chromatography accounts for the safety and quality of various substances, from commercial sodas to natural pond water. To identify low levels of volatile organic compounds or any other compounds during these substances, a gas chromatograph needs an autosampler which includes a purge and trap concentrator. Typically, researchers select the autosampler depending on the criteria above, and often consider purchasing it used to cut costs.